ASTM C ASTM does not give any warranty express or implied or make any A copy of the standard may be purchased from ASTM International, phone. Find the most up-to-date version of ASTM C at Engineering CHEMICAL RESISTANT HEAVY DUTY FLOOR BRICK. SPECIFICATION. ASTM C ASTM C STANDARD. PROPERTIES. TYPE I. TYPE II. TYPE III.

Author: Mojora Bazil
Country: Norway
Language: English (Spanish)
Genre: Life
Published (Last): 18 February 2004
Pages: 91
PDF File Size: 8.62 Mb
ePub File Size: 4.99 Mb
ISBN: 888-3-68114-470-7
Downloads: 54535
Price: Free* [*Free Regsitration Required]
Uploader: Fenrirr

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. In chemically resistant floors polyethylene foam backer rods are recommended. Expansion joints should be inspected frequently as part of a normal maintenance program.

Chemical Resistant Brick: Product Data Sheet

Cost information for a particular project and application can be obtained from authorized distributors in the individual project area. This abstract is a brief summary of the referenced standard.

BoxAatm, Ohio The brick and tile are normally used with chemical-resistant mortars. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application.

The masonry units asrm undergo tests and adhere accordingly to the following physical and chemical requirements: This specification covers chemical-resistant masonry units, specifically, solid kiln fired bricks and tiles made from clay, shale, or mixtures thereof, suitable for indoor and outdoor use in masonry construction astn to chemical environments. Sealants and back-up foam rods are limited life materials and must be replaced at the first sign of deterioration in order to prevent corrosive reagents from penetrating and undermining the chemically resistant brick floor.

Related Articles  BU2508DF PDF

Type I, for use where low absorption and high acid resistance are not major factors; Type II, for use where lower absorption and higher acid resistance are required; and Type III, for use where minimum absorption and maximum acid resistance are required. As an article, an MSDS is not required and the product is exempt from all other requirements of the hazardous communication standard.

Available in all 50 states, Canada and for export. Practices developed from experience coupled with standard control methods must be utilized in designing compensation for movement. Movement occurs in brick floors due to contraction of concrete, mortars and grouts; expansion due to heat and the growth of the ceramic materials, and differential movements between walls, floors, columns and other building elements.

ASTM C – 13 Standard Specification for Chemical-Resistant Masonry Units

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Cleaning compound such aatm phosphoric acid, trisodium phosphate, sodium hypochlorite and chlorine, bromine or iodine- releasing agents may attach the flooring materials.

Finished face on shale vertical fibre and fireclay pavers are available in wirecut texture only. Care in handling pre-waxed floor brick must be taken to avoid stacking brick at the job with a waxed surface contacting an unwaxed surface.

Related Articles  REXROTH CERAM VALVE PDF

The bricks and tiles are considered to be of three types as follows: The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Link to Active This link will sstm route to the current Active version of the standard. The recommendations of the grout or mortar manufacturer must be obtained to positively establish the chemical and thermal resistance of a particular flooring system.

ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. Table 2 C Table 2 C Historical Version s – view previous versions of standard.

Installed costs will vary by types of cc279, floor membrane and mortar requirements, types of construction, location of project and local bidding practices. Expansion and Contraction Joints: Joint sealants used must be chemically resistant, elastic and bond extremely well with the brick.

Grout and mortar for joints in brick, and mortar for bedding brick as well as chemical resistant membranes must be selected to meet anticipated corrosive and thermal conditions. Modulus of Rupture Min.